管(guan)道壁厚計算(suan)方法大多等(deng)效或參照(zhao)采用ASME等(deng)標(biao)準(zhun)規范體(ti)系。因國(guo)內行(xing)業(ye)分工不同導致管(guan)道類別較多。


1. 工業管(guan)道(dao)與國外規范的比較


  GB/T 20801《壓(ya)力管(guan)(guan)(guan)道(dao)規(gui)(gui)范(fan)(fan)(fan) 工(gong)業管(guan)(guan)(guan)道(dao)》因被國家安(an)全技(ji)術法規(gui)(gui)TSG D0001《壓(ya)力管(guan)(guan)(guan)道(dao)安(an)全技(ji)術監察規(gui)(gui)程工(gong)業管(guan)(guan)(guan)道(dao)》引用(yong)(yong)而成為強制(zhi)標準,與常用(yong)(yong)的(de)SH/T 3059《石油化工(gong)管(guan)(guan)(guan)道(dao)設計(ji)器材選用(yong)(yong)規(gui)(gui)范(fan)(fan)(fan)》、DL/T 5054《火力發電廠汽水管(guan)(guan)(guan)道(dao)設計(ji)規(gui)(gui)范(fan)(fan)(fan)》、GB 50316《工(gong)業金屬管(guan)(guan)(guan)道(dao)設計(ji)規(gui)(gui)范(fan)(fan)(fan)》等(deng)標準等(deng)同(tong)采(cai)用(yong)(yong)了(le)ASME B31.3管(guan)(guan)(guan)道(dao)壁厚計(ji)算公式,計(ji)算時材料許用(yong)(yong)應力取值(zhi)稍(shao)有差別。


  目前ASME B31.3的有效版本在分母(mu)SE項(xiang)增加了(le)一個(ge)焊接接頭強度降低系數,GB/T20801和SH/T3059也進行(xing)了(le)修改(gai)。


  GB 50316 是(shi)國家強(qiang)制標(biao)準,仍然有效,將(jiang)要發布的新版規(gui)范內也將(jiang)增加焊(han)接接頭強(qiang)度降低系數,但其許(xu)用應力取(qu)值偏保守。


  動(dong)力(li)管(guan)(guan)道(dao)規范(fan)(fan)ASME B31.1 僅(jin)對焊接(jie)(jie)鋼(gang)管(guan)(guan)而不對無縫鋼(gang)管(guan)(guan)增(zeng)加焊接(jie)(jie)接(jie)(jie)頭強(qiang)度降低系(xi)數,這點與國(guo)內電力(li)行業的(de)動(dong)力(li)管(guan)(guan)道(dao)規范(fan)(fan)是一致(zhi)的(de)。DL/T 5054與現行的(de)ASME B31.1是一致(zhi)的(de),許用應力(li)取值相對于ASME B31.3高,特(te)別(bie)是無縫鋼(gang)管(guan)(guan)在(zai)蠕變溫(wen)度下的(de)計算(suan)結(jie)果比工藝管(guan)(guan)道(dao)要小得(de)多。國(guo)內各(ge)工業管(guan)(guan)道(dao)規范(fan)(fan)因標準不同可能導致(zhi)管(guan)(guan)道(dao)壁厚計算(suan)和取值結(jie)果完全不同。


2. 國內工(gong)業管道(dao)規范(fan)和長輸(shu)管道(dao)、公用(yong)管道(dao)規范(fan)的比較


  GB 50253《輸(shu)油管(guan)道設(she)計規(gui)范(fan)》、GB 50251《輸(shu)氣(qi)管(guan)道設(she)計規(gui)范(fan)》主要(yao)參(can)照(zhao)ASME B31.4《液態烴(jing)和其他(ta)液體管(guan)線輸(shu)送(song)系統》、ASME B31.8《輸(shu)氣(qi)和配氣(qi)管(guan)道系統》。


  無(wu)論是(shi)長(chang)輸(shu)(shu)管(guan)(guan)道(dao)(dao)還是(shi)燃氣(qi)管(guan)(guan)道(dao)(dao),均引入(ru)了設計系數(shu)的(de)概念(nian)。因(yin)長(chang)輸(shu)(shu)管(guan)(guan)道(dao)(dao)和(he)(he)燃氣(qi)管(guan)(guan)道(dao)(dao)許用(yong)(yong)(yong)應力取(qu)值相對較高且不(bu)考慮腐蝕裕度(因(yin)有陰極保(bao)護(hu))和(he)(he)負(fu)偏差(cha)(cha)(設計系數(shu)中已考慮)等厚(hou)度附加量,同等條件下,長(chang)輸(shu)(shu)管(guan)(guan)道(dao)(dao)和(he)(he)公用(yong)(yong)(yong)管(guan)(guan)道(dao)(dao)的(de)壁厚(hou)計算和(he)(he)取(qu)值比工業(ye)管(guan)(guan)道(dao)(dao)要薄很多。當工業(ye)管(guan)(guan)道(dao)(dao)與長(chang)輸(shu)(shu)管(guan)(guan)道(dao)(dao)、公用(yong)(yong)(yong)管(guan)(guan)道(dao)(dao),或不(bu)同設計系數(shu)長(chang)輸(shu)(shu)管(guan)(guan)道(dao)(dao)、公用(yong)(yong)(yong)管(guan)(guan)道(dao)(dao)之間直(zhi)接焊(han)接連接時,因(yin)壁厚(hou)差(cha)(cha)異不(bu)宜直(zhi)接用(yong)(yong)(yong)打破口的(de)形(xing)式連接,而是(shi)要加一段(duan)過(guo)渡管(guan)(guan)段(duan)。


3. 負壓工況下管(guan)道壁厚校(xiao)核


  上面對各種標準規范在內壓(ya)下壓(ya)力管(guan)(guan)道的壁厚(hou)(hou)計算進(jin)行了比較分析,按內壓(ya)壁厚(hou)(hou)計算并考慮其他(ta)因素選取(qu)的壁厚(hou)(hou)可(ke)保證(zheng)壓(ya)力管(guan)(guan)道的強(qiang)度(du)在內壓(ya)下不會失效(xiao)。有時(shi)還要考慮外壓(ya)工況下,特別是大(da)口徑薄壁管(guan)(guan)道,應校核管(guan)(guan)道的壁厚(hou)(hou)或許用(yong)外壓(ya),確保管(guan)(guan)道剛度(du)和安全(quan)運行。


(1)ASME B31.3對直管外壓(ya)下(xia)壁厚計算(suan)和加(jia)強圈(quan)要求,應符(fu)合ASME規范(fan)第VII 卷第1冊UG-28。


(2)GB/T 20801對(dui)(dui)直管的外壓(真空)設(she)(she)計(ji)(ji)是按(an)GB/T 150。同(tong)時(shi)對(dui)(dui)L/T≥25且(qie)D/T。≥65,當設(she)(she)計(ji)(ji)溫度不超過(guo)300℃時(shi),可簡(jian)化公式(shi)(3.3.9)計(ji)(ji)算(suan)許用(yong)外壓。GB/T 20801簡(jian)化的許用(yong)外壓計(ji)(ji)算(suan)公式(shi)和(he)GB/T 150的計(ji)(ji)算(suan)結(jie)果(guo)是一致的。ASME 規范第(di)(di)VII卷第(di)(di)1冊UG-28在相同(tong)條(tiao)件下(xia)也可得出相同(tong)得結(jie)果(guo)。


(3)如(ru)果(guo)許用(yong)外壓不滿足(zu)設計(ji)條件,可(ke)按GB/T 150或ASME 規范第VII卷第1冊UG-29、UG-30設計(ji)加強圈。