1. 氫氣(qi)管道最(zui)大流速
碳素鋼管(guan)中氫氣最大流速,應符合表4.7.3的規定(ding)。
2. 氫氣(qi)管(guan)道管(guan)子(zi)和管(guan)件的選用(yong)
a. 氫氣(qi)管道(dao)的管材應(ying)采用無縫(feng)鋼管。氫氣(qi)管道(dao)的連(lian)(lian)接,應(ying)采用焊接。但(dan)與(yu)設備、閥門(men)的連(lian)(lian)接,可采用法蘭或(huo)錐(zhui)管螺(luo)(luo)紋連(lian)(lian)接。螺(luo)(luo)紋連(lian)(lian)接處,應(ying)采用聚(ju)四氟乙烯薄膜作為填料。
b. 氫氣管(guan)(guan)(guan)道穿(chuan)過墻壁或(huo)樓板時(shi),應(ying)敷設在(zai)套管(guan)(guan)(guan)內(nei),套管(guan)(guan)(guan)內(nei)的管(guan)(guan)(guan)段不應(ying)有焊縫。管(guan)(guan)(guan)道與(yu)套管(guan)(guan)(guan)間,應(ying)采(cai)用不燃材料填塞。氫氣管(guan)(guan)(guan)道與(yu)其(qi)他管(guan)(guan)(guan)道共(gong)架敷設或(huo)分層(ceng)(ceng)布置(zhi)時(shi),氫氣管(guan)(guan)(guan)道宜布置(zhi)在(zai)外側并(bing)在(zai)上層(ceng)(ceng)。
c. 當操(cao)作溫度≥200℃時,按臨氫(qing)(qing)作業(ye)用鋼(gang)(gang)防(fang)止(zhi)脫碳和微裂的操(cao)作極限(Nelson 曲(qu)線)選擇(ze)適(shi)當的抗氫(qing)(qing)鋼(gang)(gang)材(cai),參照API RP 941《煉油(you)廠和石油(you)化工廠用高(gao)溫高(gao)壓臨氫(qing)(qing)作業(ye)用鋼(gang)(gang)》。
3. 工程應用
某操(cao)作溫度為160℃的(de)氫氣(qi)管道,管子(zi)材質(zhi)選用ASTM A234 Gr.WPB,管件選用ASTMA234 Gr.WPB。
WPB材料(liao)是國(guo)內外比較(jiao)常用的(de)中(zhong)、高溫條件下的(de)碳鋼管件材料(liao),其來源可(ke)以(yi)是鋼管(如ASTM A106 Gr.C),也可(ke)以(yi)是鋼板(如ASTM A285 GR.C)。國(guo)標(biao)GB/T 8163的(de)20#及(ji)GB 5310的(de)20G無縫(feng)鋼管,GB/T 3274的(de)Q235A、Q235B中(zhong)厚板的(de)化學成分及(ji)機械性指標(biao)與ASTMA234GR.WPB 比較(jiao),國(guo)標(biao)滿足(zu)WPB材料(liao)要(yao)求。
4. 氫氣管道設計常用標準規范
ASME B31.12《氫用管道和管線(xian)》
API RP 941《煉油廠和石油化工(gong)廠用高(gao)溫高(gao)壓臨(lin)氫作業(ye)用鋼》
GB 50177《氫氣站設計規范(fan)》
GB 4962《氫(qing)氣使用安(an)全技術規程》
SY/T 4117《高含硫化(hua)氫(qing)氣田集輸管道焊接技術規(gui)范》