1. 伴管管徑及根(gen)數的選用
①. 伴管管徑宜為10、12、DN15、DN20、DN25,伴管根(gen)數不宜超(chao)過(guo)4根(gen)。
②. 在(zai)不同環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)及工藝(yi)操作條件下,蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)管(guan)(guan)徑及根數從SH/T 3040提供的(de)四個表(biao)(biao)(表(biao)(biao)1蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)143℃/183℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)5℃;表(biao)(biao)2蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)143℃/183℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-5℃;表(biao)(biao)3蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)143℃/183℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-15℃;表(biao)(biao)4蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)143℃/183℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-25℃)中選擇;熱水伴(ban)管(guan)(guan)管(guan)(guan)徑及根數從SH/T 3040提供的(de)四個表(biao)(biao)(表(biao)(biao)5蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)90℃/100℃/110℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)5℃;表(biao)(biao)6蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du) 90℃/100℃/110℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-5℃;表(biao)(biao)7蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)90℃/100℃/110℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-15℃;表(biao)(biao)8蒸(zheng)(zheng)(zheng)汽伴(ban)管(guan)(guan)溫(wen)(wen)(wen)(wen)(wen)度(du)90℃/100℃/110℃、環(huan)(huan)境溫(wen)(wen)(wen)(wen)(wen)度(du)-25℃)中選擇。
③. 環境溫度(du)、伴管(guan)(guan)介質(zhi)的操(cao)作條件(jian)、保溫材料制品的熱導率及(ji)傳熱系數(shu)等數(shu)據與(yu)表1~表8不同時,伴管(guan)(guan)管(guan)(guan)徑及(ji)根(gen)數(shu)(采(cai)用(yong)硬(ying)質(zhi)或(huo)半硬(ying)質(zhi)圓形(xing)保溫材料制品)按下(xia)面(mian)公式計算。
2. 蒸(zheng)汽分配(pei)站(zhan)和疏水站(zhan)
①. 對于蒸汽(qi)分配(pei)站和(he)疏(shu)水站的管徑(jing)也給(gei)出(chu)了下面的公式,計算出(chu)S值,再查詢(xun)SH3040相應(ying)的表格來獲得蒸汽(qi)分配(pei)站和(he)疏(shu)水站的管徑(jing)。
S=A+2B+3C 式中(zhong)A-DN15、612、10伴管根(gen)數(shu)(shu);B-DN20伴管根(gen)數(shu)(shu);C-DN25伴管根(gen)數(shu)(shu)。
②. 在3m半徑(jing)范(fan)圍內如有3個(ge)或3個(ge)以(yi)上的伴(ban)(ban)熱(re)點(dian)(dian)及回收點(dian)(dian)時,蒸(zheng)汽伴(ban)(ban)熱(re)系統應設置蒸(zheng)汽分配(pei)站(zhan)(zhan)和疏水(shui)站(zhan)(zhan),熱(re)水(shui)伴(ban)(ban)熱(re)系統應設置熱(re)水(shui)分配(pei)站(zhan)(zhan)和熱(re)水(shui)回水(shui)站(zhan)(zhan)。站(zhan)(zhan)的設置應考慮統一考慮,布局合理,方(fang)便操(cao)作和維修。
3. 蒸(zheng)汽伴管(guan)沿被伴熱管(guan)的最大允許有效伴熱長度(du)(包括垂直(zhi)管(guan)道)(表6-34)
凝結水(shui)不回(hui)收時,最大(da)允許(xu)有(you)效伴(ban)熱長(chang)(chang)度(du)可延長(chang)(chang)20%;采用導熱膠泥(ni)時,最大(da)允許(xu)有(you)效伴(ban)熱長(chang)(chang)度(du)宜(yi)縮短(duan)20%;對于出現U形彎時,在超(chao)過規(gui)定數值(蒸汽壓力0.3~0.5MPa,累(lei)(lei)計(ji)上(shang)升(sheng)4m;蒸汽壓力大(da)于0.5~0.7MPa,累(lei)(lei)計(ji)上(shang)升(sheng)5m;蒸汽壓力大(da)于0.7~1MPa,累(lei)(lei)計(ji)上(shang)升(sheng)6m)時宜(yi)適當減(jian)少最大(da)允許(xu)有(you)效伴(ban)熱長(chang)(chang)度(du),但(dan)伴(ban)管累(lei)(lei)計(ji)上(shang)升(sheng)高(gao)度(du)不宜(yi)超(chao)過10m。
注:1. 蒸(zheng)(zheng)(zheng)汽分配(pei)站安裝位置高(gao)于蒸(zheng)(zheng)(zheng)汽總管時,分配(pei)站低(di)點可不設排放冷(leng)凝水的(de)(de)蒸(zheng)(zheng)(zheng)汽疏水閥系統,水平安裝的(de)(de)分配(pei)站應無袋形并坡(po)向蒸(zheng)(zheng)(zheng)汽總管。蒸(zheng)(zheng)(zheng)汽分配(pei)站低(di)于蒸(zheng)(zheng)(zheng)汽總管時,其上游不得有(you)下(xia)凹的(de)(de)袋形彎,分配(pei)站的(de)(de)低(di)點應設蒸(zheng)(zheng)(zheng)汽疏水閥組。
2. 蒸汽(qi)分配站至少有3根伴(ban)管(guan)(DN15)送至半(ban)徑(jing)為3m范圍內(nei)的地點時才設置,否則伴(ban)熱供汽(qi)管(guan)可直(zhi)接從蒸汽(qi)總管(guan)上引出(chu)。
3. 分配站(zhan)應布置(zhi)在不(bu)妨礙通行(xing)、便于操作(zuo)的(de)地方,布置(zhi)應考慮整齊和美觀(guan)。
4. 供(gong)汽管的閥門應布(bu)置在便于接近的地(di)方。
5. 分配站(zhan)的(de)蒸汽(qi)應從蒸汽(qi)總(zong)管的(de)頂(ding)部引(yin)出(chu)。
4. 熱水(shui)伴管沿(yan)被伴熱管的最大允(yun)許有(you)效伴熱長度(du)(包括(kuo)垂(chui)直管道)(表6-35)
注:按SH/T 3040,應注意有效伴熱長度和其他標(biao)準規(gui)定的數值(zhi)的不同,根(gen)據項目(mu)實(shi)際(ji)情況(kuang)選用(yong)。
注(zhu)(zhu):按 SH/T 3040,應注(zhu)(zhu)意有效伴熱長度和其(qi)他標準規(gui)定(ding)的數值的不(bu)同,根(gen)據(ju)項目(mu)實際情況選用。